Rapid crack propagation ISO 13477 on HDPE pipes RCP Tester

ISO 13477 RCP Tester (S4 Test)

Rapid crack propagation ISO 13477 on HDPE pipes RCP Tester

Rapid crack propagation ISO 13477 on HDPE pipes RCP tester

Rapid Crack Propagation Tester (RCP)

Rapid crack propagation ISO 13477 on HDPE pipes RCP test

RCP is used to determine the critical pressure or critical temperature for rapid crack propagation.

ISO 13477 Thermoplastics pipes for the conveyance of fluids- Determination of resistance to rapid crack propagation (RCP) —Small-scale steady-state test (S4 test)

RCP Test Unit

 Characteristics

         Rapid crack propagation ISO 13477 on HDPE pipes RCP ester

  1. Rational structure and accurate impact speed. There is energy storage device in basic unit, which shall convert elastic potential energy into kinetic energy, that the impact speed range can be controlled between 1mis and 20m/s.
  2. lndustrial control terminal was introduced and colorful touch screen display provides more information to operator, such as sample pretreatment time, pipe inside current pressure, impact speed, length of crack and test temperature,
  3. Fast pressure filling and accurate pressure For pipes DN200 to DN500, setting pressure can be arrived within 30s.
  4. Thanks to the module design, system can be updated and extended to be suitable for different sizes of
  5. High rigid frame enhance the bearing strength of system and multiple buffers in the frame reduce impact force from the high velocity striker, so that the component connection keep perfect after repeated
  6. High-efficiency and reliable energy storage system. Energy storage system with a high storage speed and striker lifting system can be locked firmly or released quickly.
  7. The easily adjustable support and the simple assembly & positioning system with quick coupling saves time and has proved to work outstandingly well in operation with
  8. Automatic security confirmation system. It means the correct locations of the test sample and the striker blade are identified automatically, so that the collision of the sample assembly with the striker blade is prohibited and the blade will not be released when the sample is not in

 

RCP Low Temperature Conditioning Cabinet (optional)

  1. Automatically-activated doors are provided. For time-saving reasons, the assembly goes into and out of the

conditioning cabinet through the pneumatic opening door.

  1. Ultralow temperature and high efficiency. Temperature can drop to -30 within 1Omin and multiple groups of samples can be treated simultaneously.. Temperature can be monitored and regulated
  2. There are independent sample delivery rails for cooling stations. Unique sealing design for the cabinet avoid freezing phenomenon between sealing strip and
  3. Excellent thermal insulation system helps to enhance the security and save power
  4. Multiple safety protection systems, including escape and alarm device for

 

RCP Sample Feeding Unit:

As the standard laying down the “crack initiation shall follow within 3 minutes of removal of the test pipe from the conditioning”, limited time is available to position test sample and to increase the internal pressure. For this reason we offer a complete electric sample delivery unit.

Characteristics

  1. High accuracy and high delivery

Thanks to the positioning system and automatic driven system, sample can be picked up from the conditioning cabinet within 30s. 2.PLC control terminal and colorful touch screen.

Integrated monitoring during testing and provides customer more information, such as cooling temperature, pretreatment time, sample inlet& outlet, etc.

 

 

RCP End Caps:

Rapid crack propagation ISO 13477 on HDPE pipes RCP ester

It consists of front & rear sealing part, limiting ring, baffles, o-rings, etc.    

A variety of specifications are selected,

Including φ32mm, φ63mm, φ110mm, φ160mm, φ250mm, φ315mm, φ400mm and φ500mm, etc.

 

 

Parameters:

Rapid crack propagation ISO 13477 on HDPE pipes RCP ester

                  Test pipe sizes32mm-250mm
Impact speed of strike    blade5m/s to 20m/s, at the step of 0.5/s
Speed accuracy土0.5m/s
 

Pressure

Pressure mediumNitrogen (equipped by user)
Range≤2.5MPa
Accuracy classGrade:0.5
Control modePLC control and touch screen display
Striker blade releasePneumatic
Pneumatic energy storageMotor-driven
Speed measurementIndependent measurement, serial communication interface
                   Storage modeUSB Stick
                 Power supply220VAC   50Hz 1KW
Compressed air interface3/8 ” quick coupling, high pressure hose
Compressed a 「supply3- 4Mpa (equipped by user)      
Security protectionIP55
Basic unitWeight500kg
Dimension (LxWxH)(1200*590*2850)mm
Main

controller

Weight80kg
Dimension (LxWxH)(800*460*1080)mm
RCP Low temperature conditioning cabinet (optional)
Test stations1
Cubage1 stations1800*4600*2300
Temperature  control  range0°C~ -30°C
Temperature display accuracy0.1°C
Cooling power1 station5P, Hourly  cooling capacity:10.7KW
Power supply380VAC 50HZ  5KW
Weight650kg
RCP sample delivery system
Control modePLC control and touch screen display
                    Number of test station1
                  Sample deliveryPneumatic and motor-driven
Sample delivery distance (Automatic)3400mm
Sample delivery speed370mm/s
Longest time for sample delivery33s
Compressed air supply<0.8Mpa   (equipped by user)
              Power supply220VAC  50HZ 300W
           Weight300kg
                 Dimension (LxWx H)1100mm×1800mm×2850mm

For more info, please contact us:
Email: andy@victorytest.com
Mobile & WeChat & WhatsApp: +86-15305307234

Share this post